Product Introduction
	
	
| 
					 model  | 
				
					 S-60-5(Min)  | 
				
					 S-60-12(Min)  | 
				
					 S-60-24(Min)  | 
				
					 S-60-48(Min)  | 
				
					 
  | 
			|
| 
					 output  | 
				
					 Dc output voltage  | 
				
					 12V  | 
				
					 12V  | 
				
					 12V  | 
				
					 12V  | 
				
					 
  | 
			
| 
					 Output voltage tolerance  | 
				
					 ±1%  | 
				
					 ±1%  | 
				
					 ±1%  | 
				
					 ±1%  | 
				
					 
  | 
			|
| 
					 Rated output current  | 
				
					 12A  | 
				
					 5A  | 
				
					 2.5A  | 
				
					 1.25A  | 
				
					 
  | 
			|
| 
					 Output current range  | 
				
					 0-12A  | 
				
					 0-5A  | 
				
					 0-2.5A  | 
				
					 0-1.25A  | 
				
					 
  | 
			|
| 
					 Output power  | 
				
					 60W  | 
				
					 60W  | 
				
					 60W  | 
				
					 60W  | 
				
					 
  | 
			|
| 
					 Ripple and the noise  | 
				
					 120mVp-p  | 
				
					 120mVp-p  | 
				
					 120mVp-p  | 
				
					 120mVp-p  | 
				
					 
  | 
			|
| 
					 Dc voltage adjustable scope  | 
				
					 ±10%  | 
				
					 ±10%  | 
				
					 ±10%  | 
				
					 ±10%  | 
				
					 
  | 
			|
| 
					 Start, rise, keep time  | 
				
					 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC  | 
			|||||
| 
					 input  | 
				
					 Input voltage range  | 
				
					 90 ~264VAC 47~63 Hz;120~370VDC  | 
			||||
| 
					 Exchange input current  | 
				
					 2A/115 V 1A/ 230 V  | 
			|||||
| 
					 efficiency  | 
				
					 82%  | 
				
					 82%  | 
				
					 82%  | 
				
					 82%  | 
				
					 
  | 
			|
| 
					 Impulse current  | 
				
					 Cold start current 30A/115VAC 60A/230VAC  | 
			|||||
| 
					 Leakage current  | 
				
					 <3.5 mA/240VAC  | 
			|||||
| 
					 Protection characteristics  | 
				
					 Overload protection  | 
				
					 115%~165%  | 
			||||
| 
					 Protection way: current limiting, automatic recovery  | 
			||||||
| 
					 Over-voltage protection  | 
				
					 115%~135%  | 
			|||||
| 
					 Protection way: hiccups, auto recovery mode  | 
			||||||
| 
					 environment  | 
				
					 Working temperature, humidity  | 
				
					 -10℃~+60℃;20%~90 %RH  | 
			||||
| 
					 Keep temperature, humidity  | 
				
					 -20℃~+85℃;10%~95 %RH  | 
			|||||
| 
					 Vibrate resistance  | 
				
					 10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis  | 
			|||||
| 
					 security  | 
				
					 Compression sex  | 
				
					 3: KVAC between input and output and input and output KVAC: 1.5 to 0.5: KVAC  | 
			||||
| 
					 Insulation resistance  | 
				
					 
						Between the input and output, the input and output, and ground:  | 
			|||||
| 
					 standard  | 
				
					 Safety standards  | 
				
					 
						Accord with  | 
			||||
| 
					 EMC standards  | 
				
					 
						Accord with  | 
			|||||
| 
					 other  | 
				
					 weight  | 
				
					 0.26Kg  | 
			||||
| 
					 packaging  | 
				
					 50pcs/14.5Kg/54.5×35×25.7Cm /0.049CBM/  | 
			|||||
| 
					 note  | 
				
					 
						1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.  | 
			|||||
	
	


                        