•  60W 12V-5A Mini Size
  •  60W 12V-5A Mini Size
  •  60W 12V-5A Mini Size
60W 12V-5A Mini Size  60W 12V-5A Mini Size  60W 12V-5A Mini Size

Product Introduction



model

S-60-5Min

S-60-12Min

S-60-24Min

S-60-48Min

 

output

Dc output voltage

12V

12V

12V

12V

 

Output voltage tolerance

±1%

±1%

±1%

±1%

 

Rated output current

12A

5A

2.5A

1.25A

 

Output current range

0-12A

0-5A

0-2.5A

0-1.25A

 

Output power

60W

60W

60W

60W

 

Ripple and the noise

120mVp-p

120mVp-p

120mVp-p

120mVp-p

 

Dc voltage adjustable scope

±10%

±10%

±10%

±10%

 

Start, rise, keep time

800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC

input

Input voltage range

90 264VAC 4763 Hz120370VDC

Exchange input current

2A/115 V 1A/ 230 V

efficiency

82%

82%

82%

82%

 

Impulse current

Cold start current 30A/115VAC 60A/230VAC

Leakage current

3.5 mA/240VAC

Protection characteristics

Overload protection

115%165%

Protection way: current limiting, automatic recovery

Over-voltage protection

115%135%

Protection way: hiccups, auto recovery mode

environment

Working temperature, humidity

-10℃+60℃20%90 %RH

Keep temperature, humidity

-20℃+85℃10%95 %RH

Vibrate resistance

10500Hz2G 10min./1 cycle time, 60 minutes, the axis

security

Compression sex

3: KVAC between input and output and input and output KVAC: 1.5 to 0.5: KVAC

Insulation resistance

Between the input and output, the input and output, and ground:
100M Ohms/500VDC

standard

Safety standards

Accord with
UL1012, UL1950TUV EN60950

EMC standards

Accord with
EN55022EN61000-3-2-3EN61000-4-23456811ENV50204EN55024

other

weight

0.26Kg

packaging

50pcs/14.5Kg/54.5×35×25.7Cm /0.049CBM/

note

1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.
5. Specific output current see output drop forehead curve