Model |
DR-120-12 |
DR-120-15 |
DR-120-24 |
DR-120-48 |
DC output voltage |
12V |
15V |
24V |
48V |
Output voltage range |
±2% |
±2% |
±1% |
±1% |
Rated output current |
10A |
8A |
5A |
2.5A |
Output current range |
0-10A |
0-8A |
0-5A |
0-2.5A |
Wave and noise |
85mVp-p |
85mVp-p |
85mVp-p |
100mVp-p |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±1% |
±1% |
±1% |
±1% |
DC output power |
120W |
120W |
120W |
120W |
Efficiency |
80% |
81% |
84% |
85% |
Adjustable range for DC voltage |
10.8~13.2V |
13.5~16.5V |
21.6~26.4V% |
43.2~52.8V% |
AC input voltage range |
88~132VAC 47~63Hz;240~370VDC |
|||
Input current |
3.3A/115V 2A/230V |
|||
AC inrush current |
Cold-start current 30A/115V 60A/230V |
|||
Leakage current |
<3.5mA/240VAC |
|||
Overload protection |
105%~150% Type: pulsing hiccup shutdown Reset: tuto recovery |
|||
Over-voltage protection |
13.8~16.2V |
18~21V |
27.6~32.4V |
58~62V |
Temperature coefficient |
±0.03%/°c(0~50°c) |
|||
Setup, rise , hold up time |
500ms,70ms, 50ms/230V |
|||
Vibration |
10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes |
|||
Withstand voltage |
Input and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC |
|||
Isolation resistance |
Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ |
|||
Working temperature and humidity |
10°c~50°c(Refer to output derating curve), 20%~90%RH |
|||
Overall dimension |
65.5×125.2×100mm |
|||
Weight |
0.8Kgs 24PCS/19.2Kg/1.1CUFT |
|||
Safety standards |
Meet UL 1012 requiement (Not apply for the mark) |
|||
EMC standards |
Meet FCC PART 15 J Conduction class B |