Product Introduction
55W Single Output with Battery Charger (UPS Function)
·Universal AC input/full range
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage
·LED indicator for power on
·Battery protection at low voltage
·100% full load burn-in test
·3 Years warranty
		
	
| 
					 Model  | 
				
					 SD-55-12  | 
				
					 SD-55-24  | 
			|||
| 
					 Output  | 
				
					 DC voltage  | 
				
					 CH1:13.8V  | 
				
					 CH2:13.4V  | 
				
					 CH1:27.6V  | 
				
					 CH2:26.5V  | 
			
| 
					 Voltage tolerance  | 
				
					 ±1%  | 
				
					 -----  | 
				
					 ±1%  | 
				
					 -----  | 
			|
| 
					 Rated current  | 
				
					 3.5A  | 
				
					 0.23A  | 
				
					 1.8A  | 
				
					 0.16A  | 
			|
| 
					 Current range  | 
				
					 0~4.0A  | 
				
					 -----  | 
				
					 0~2A  | 
				
					 -----  | 
			|
| 
					 Rated power  | 
				
					 51.38W  | 
				
					 53.92W  | 
			|||
| 
					 Ripple&Noise  | 
				
					 100mVp-p  | 
				
					 -----  | 
				
					 100mVp-p  | 
				
					 -----  | 
			|
| 
					 DC Voltage ADJ. range  | 
				
					 CH1:11.3~14.9V  | 
				
					 CH1:21.3~29.8V  | 
			|||
| 
					 Setup,Rise,Hold up time  | 
				
					 800ms,50ms,80ms/230VAC.1600ms,50ms,16ms/115VAC.  | 
			||||
| 
					 Input  | 
				
					 Voltage range  | 
				
					 90~264VAC or 127~370VDC  | 
			|||
| 
					 Ac current  | 
				
					 1.6A/115VAC 1A/230VAC  | 
			||||
| 
					 Efficiency  | 
				
					 71%  | 
				
					 74%  | 
			|||
| 
					 Inrush current  | 
				
					 cold start 20A/115VAC 40A/230VAC  | 
			||||
| 
					 Leakage current  | 
				
					 <1mA/240VAC  | 
			||||
| 
					 Protection  | 
				
					 Over load  | 
				
					 110%~150% Rated output power  | 
			|||
| 
					 Protection type : AC charging mode Hiccup mode,recovers automatically after fault condition is removed ;UPS Mode : Protected by internal fuse  | 
			|||||
| 
					 over voltage  | 
				
					 CH1:15.9~18.8V  | 
				
					 CH1:31.7~37.5V  | 
			|||
| 
					 Protection type : Hiccup mode,recovers automatically after fault condition is removed ;  | 
			|||||
| 
					 Battery low  | 
				
					 9.5~11V  | 
				
					 20~22V  | 
			|||
| 
					 Function  | 
				
					 DC alarm signal(optional)  | 
				
					 AC fail CN1 PIN2  | 
			|||
| 
					 Battery low under charge voltage 82.5%± 2% CN1 PIN1  | 
			|||||
| 
					 Normal 0.8V max. Abnormal 5V±0.5V  | 
			|||||
| 
					 Environment  | 
				
					 Working temp,humidity  | 
				
					 -10℃~+60℃;20%~90%RH(Refer to "Deration Curve")  | 
			|||
| 
					 Storage temp,humidity  | 
				
					 -20℃~+85℃;10%~95%RH non-condensing  | 
			||||
| 
					 vibration  | 
				
					 10~500Hz,2G 10min./1cycle,period for 60min,each along X,Y,Z axes  | 
			||||
| 
					 Safety  | 
				
					 Withstand voltage  | 
				
					 I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC  | 
			|||
| 
					 Isolation resistance  | 
				
					 I/P-O/P: I/P-FG,O/P-FG:100M Ohms/500VDC  | 
			||||
| 
					 EMC  | 
				
					 Safety standard  | 
				
					 Compliance UL60950-1  | 
			|||
| 
					 EMC  | 
				
					 Compliance EN55022,EN55024,CLASS B  | 
			||||
| 
					 Others  | 
				
					 Dimension  | 
				
					 0.52kg 159*97*38mm(L*W*H)  | 
			|||
| 
					 Packing  | 
				
					 0.52kg/45pcs/24kg  | 
			||||
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
		
	


                        