•  SC-60-12 Min UPS Power
  •  SC-60-12 Min UPS Power
SC-60-12 Min UPS Power  SC-60-12 Min UPS Power

Product Introduction


 

·Universal AC input range

·Small volumelow weighthigh efficiency

·Protections:short circuit/over load

·LED indicator for power on/Charging/nomal

·Battery protection at low voltage

·100% full load burn-in test

·2 Years warranty

Model

SC-60-12 Min

SC-12-24 Min

Output

DC voltage

CH1:13.8V

CH2:13.4V

CH1:27.6V

CH2:26.5V

Voltage tolerance

±1

-----

±1

-----

Rated current

4.0A

0.35A

2.0A

0.25A

Current range

04A

-----

02A

-----

Rated power

59.9W

61.8W

Ripple&Noise

100mVp-p

-----

100mVp-p

-----

DC Voltage ADJ. range

CH1:11.314.9V

CH1:21.329.8V

Setup,Rise,Hold up time

800ms,50ms,80ms/230VAC.1600ms,50ms,16ms/115VAC.

Input

Voltage range

90264VAC or 127370VDC

Ac current

1.6A/115VAC 0.8A/230VAC

Efficiency

81%

83%

Inrush current

cold start 25A/115VAC 45A/230VAC

Leakage current

1mA/240VAC

Protection

Over load

110%150% Rated output power

Protection type : AC charging mode Hiccup mode,recovers automatically after fault condition is removed

Battery low

9.511V

2022V

Protection type : cutt off output

UPS system

long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90%

auto-stop charging when it's full,prevent over charging.Effectively extend battery life

AC/battery auto switch ,no switch time,no need human guard

cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs

Environment

Working temp,humidity

-10℃+60℃;20%90%RH(Refer to "Deration Curve")

Storage temp,humidity

-20℃+85℃;10%95%RH non-condensing

vibration

10500Hz2G   10min./1cycleperiod for 60mineach along X,Y,Z axes

Safety

Withstand voltage

I/P-O/P1.5KVAC I/P-FG1.5KVAC O/P-FG0.5KVAC

Isolation resistance

I/P-O/PI/P-FG,O/P-FG100M   Ohms/500VDC

EMC

Safety standard

Compliance EN55022EN55024, CLASS B

EMC

Compliance EN55022EN5502B4,   CLASS

Others

Dimension

0.223kg 110*78*36mm (L*W*H)

Packing

0.245kg/50pcs/13.5kg

NOTE:

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.