•  SDD-55系列UPS电源 - 副本
  •  SDD-55系列UPS电源 - 副本
SDD-55系列UPS电源 - 副本  SDD-55系列UPS电源 - 副本

产品介绍


55W Dual Output with Battery Charger (UPS Function)  

Features:

Universal AC input / Full range

Protections: Short circuit / Overload / Over voltage

Battery low protections

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at 45 KHz

1 year warranty

 

SPECIFICATION

MODEL

SDD-55-12-5

SDD-55-24-5

OUTPUT

 

 

Outputnumber

CH2

CH3

CH1

CH3

CH2

CH1

DC voltage

13.8V

5V

13.4V

5V

26.5V

27.6V

Rated Current

2.5A

3A

0.23A

1.3A

3A

0.16A

Current Range

0~3.5A

0~4A

--------

0~2A

0~4A

--------

Rated Power

52.58W

55.12W

Ripple&Noise

100mVp-p

100mVp-p

--------

150mVp-p

150mVp-p

--------

Voltage Adj.Range

CH1:12~14.5V

CH1:24~29V

Voltage Tolerance

±1.0%

3.0%

--------

±1.0%

3.0%

--------

Line Regulation

±0.5%

0.5%

--------

±0.5%

0.5%

--------

Load Regulation

±0.5%

0.5%

--------

±0.5%

0.5%

--------

Setup,Rise Time

800ms,50ms/230VAC   1600ms,50ms/115VAC at full load

Hold UpTime

80ms/230VAC    16ms/115VAC at full load

 

 

INPUT

 

Voltage Range

88~264VAC47~63Hz; 124~370VDC

AC Current

1.6A/115VAC  1A/230VAC

Efficiency

71%

74%

Inrush Current

Coldstart 20A/115VAC   40A/230VAC

Leakage Current

<1mA /240VAC

 

 

PROTECTION

 

Over Load

105~150% rated output power

Protection type:AC Charging Mode:Hiccup mode,recovers automatically after fault condition is removed UPS Mode:Protected by internal fuse

Over Voltage

CH1:14.49~18.63V

CH2:28.98~37.26V

Protection type: Hiccup mode, recovers automatically after fault condition is removed

Battery Low

9.5~11V

20~22V

 

 

ENVIRONMENT

 

Working Temp.

-10~+60℃(Refer to“Derating Curve”)

Working Humidity

20~90%RH non-condensing

Storage Temp.,Humidity

-20~+85℃,10~95%RH

Temp.Coefficient

±0.03%/ ℃(0~50℃ )on CH1 output

Vibration

10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes

 

 

SAFETY &EMC

 

Safety Standards

Design refer to UL60950-1, TUV EN60950-1

Withstand Voltage

I/P-O/P:3KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC

 

Isolation Resistance

I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH

 

EMC Emission

Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3

 

EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A

 

 

 

OTHERS

 

Dimension

159*97*38mm(L*W*H)

Weight

0.5Kg

Packing

24pcs/12.6Kg/0.75CUFT

 

 

NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.